GP25B series
August 26, 2024GSM40A series
August 26, 2024MW Mean Well Meanwell 50W AC-DC Triple Output Industrial Desktop Adaptor GP50A Series
Features
- Universal AC input / Full range
- 3 pole AC inlet IEC320-C14, Class I power unit
- No load power consumption< 0.3W
- Energy efficiency Level VI
- Comply with EISA 2007/DoE
- Protections: Short circuit / Overload / Over voltage
- Fully enclosed plastic case
- -20~+70℃ working temperature
- LED indicator for power on
- Dual output available (optional)
- ± 16V /+48V also available for video system (optional, order NO. : GP50A58F-R1B)
- 3 years warranty
Description
The GP50A is a 50W triple-output desktop green adapter series that adheres to the stringent energy-saving standards of the USA EISA 2007/DoE (Level VI). Engineered with a Class I design, it features a standard IEC320-C14 inlet, functional ground (FG), and a 94V-0 flame-retardant plastic enclosure to effectively prevent electric shock hazards.
This versatile series operates across a broad input voltage range of 90-264VAC and offers three output voltage configurations: +5V/+12V/-5V, +5V/+12V/-12V, and +5V/+15V/-15V, with an optional configuration of +16V/+48V/-16V. Key features include ultra-low no-load power consumption of less than 0.3W, reliable operation within an ambient temperature range of -20 to +70℃, comprehensive protection functions, and a three-year warranty. The GP50A is also fully compliant with international safety certifications, including CB, TUV, UL, CE, and FCC.
The GP50A is a robust multi-output green adapter offering superior safety, reliability, and quality, making it an excellent choice for various applications.
Mean Well Industrial Desktop Adaptor GP50A Series Model Encoding
Mean Well Industrial Desktop Adaptor GP50A Series Data Sheet Download
Specification
ORDER NO. | GP50A13A-R1B | GP50A13D-R1B | GP50A14E-R1B | GP50A58F-R1B (option) | |||||||||||
OUTPUT |
SAFETY MODEL NO. | GP50A13A | GP50A13D | GP50A14E | GP50A58F | ||||||||||
DC VOLTAGE Note.2 | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 16V | 48V | -16V | |||
RATED SET CURRENT | 4A | 2A | 0.5A | 4A | 2A | 0.5A | 4A | 1.5A | 0.5A | 2A | 0.15A | 2A | |||
CURRENT RANGE | 0 ~ 4.0A | 0.3 ~ 2.0A | 0.1 ~ 0.5A | 0 ~ 4.0A | 0.3 ~2.0A | 0.1 ~0.5A | 0 ~ 4.0A | 0.3 ~ 1.5A | 0.1 ~0.5A | 0.4 ~ 2.0A | 30mA ~ 150mA | 0.4 ~2.0A | |||
RATED POWER | 46.5W | 50W | 50W | 71.2W | |||||||||||
RIPPLE & NOISE (max.) Note.3 | 50mVp-p | 100mVp-p | 100mVp-p | 50mVp-p | 150mVp-p | 100mVp-p | 50mVp-p | 150mVp-p | 150mVp-p | 180mVp-p | 180mVp-p | 180mVp-p | |||
VOLTAGE TOLERANCE Note.4 | ±5.0% | ±3.0% | -5% ~ +10% | ±5.0% | ±3.0% | -5% ~ +8% | ±5.0% | ±3.0% | -5% ~ +15% | ±5.0% | -5% ~ +10% | -5% ~ +10% | |||
LINE REGULATION Note.5 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LOAD REGULATION Note.6 | ±5.0% | ±3.0% | ±5.0% | ±5.0% | ±3.0% | ±5.0% | ±5.0% | ±3.0% | ±5.0% | ±5.0% | ±5.0% | ±5.0% | |||
SETUP, RISE, HOLD UP TIME | 1500ms, 50ms, 20ms / 230VAC 2500ms, 50ms, 16ms / 115VAC at full load | ||||||||||||||
INPUT |
VOLTAGE RANGE Note.7 | 90 ~ 264VAC 135~ 370VDC | |||||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||||
EFFICIENCY (Typ.) | 83.5% | 84% | 84.5% | 86% | |||||||||||
AC CURRENT | 1.6A / 100VAC 0.8A / 230VAC | ||||||||||||||
INRUSH CURRENT (max.) | Cold start 35A/115VAC 65A / 230VAC | ||||||||||||||
LEAKAGE CURRENT (max.) | 0.75mA / 240VAC | ||||||||||||||
PROTECTION |
OVERLOAD | 120 ~ 200% rated output power | |||||||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||||
OVER VOLTAGE | Protection type: Clamp by zener diode, output short | ||||||||||||||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +70℃ (Refer to “Derating Curve”) | |||||||||||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | ||||||||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||||||||||
TEMP. COEFFICIENT | ±0.03% / ℃ (0 ~ 40℃) | ||||||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||||||||||
SAFETY & EMC (Note. 8) |
SAFETY STANDARDS | IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1(Except for GP50A58F-R1B), EAC TP TC 004 approved | |||||||||||||
WITHSTAND VOLTAGE | I/P-O/P:4242VDC, I/P-FG:2121VDC | ||||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||||||||||||
Conducted emission | BS EN/EN55032(CISPR32), FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) | Class B | |||||||||||||
Radiated emission | BS EN/EN55032(CISPR32), FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B) | Class B | |||||||||||||
Harmonic current | BS EN/EN61000-3-2 | Class A | |||||||||||||
Voltage flicker | BS EN/EN61000-3-3 | ——- | |||||||||||||
EMC IMMUNITY |
Parameter | Standard | Test Level /Note | ||||||||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact | |||||||||||||
RF field susceptibility | BS EN/EN61000-4-3 | Level 2, 3V/m | |||||||||||||
EFT bursts | BS EN/EN61000-4-4 | Level 2, 1KV | |||||||||||||
Surge susceptibility | BS EN/EN61000-4-5 | Level 3, 1KV/L-N, 2KV/L, N-PE | |||||||||||||
Conducted susceptibility | BS EN/EN61000-4-6 | Level 2, 3V | |||||||||||||
Voltage dips, interruption | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||||||||||||
OTHERS |
LIFE | 3 years: 100% load 40℃, 8hours/day | |||||||||||||
MTBF | 280K hrs min. MIL-HDBK-217F (25℃) | ||||||||||||||
DIMENSION | 146*75.5*43mm (L*W*H) | ||||||||||||||
PACKING | 0.55kg; 36pcs / 21kg / CARTON | ||||||||||||||
CONNECTOR | PLUG | See page 4 | |||||||||||||
CABLE | See page 4 |
Applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments