Mechanical Dimensions and Installation
The MEAN WELL SCP-75 Series uses an enclosed chassis for integration into DC power and battery-supported equipment. It is cooled by free-air convection and provides separate connections for AC input, regulated DC output, external battery and the optional temperature sensor.
Dimensions
The SCP-75 Series measures 159 × 97 × 38 mm (L × W × H).
The mechanical drawing shows the enclosure dimensions, mounting-hole locations, AC input terminal block, DC output terminals, battery connections, CN2 temperature-sensor connector, LED indicator and output-voltage adjustment point.
AC Input and DC Output Connections
AC input is connected through TB1, which provides terminals for:
- AC/L: AC line input
- AC/N: AC neutral input
- FG: Frame ground
The regulated DC output is available through TB2, with dedicated +V and -V terminals for the connected load.
Battery Connections
The SCP-75 Series provides dedicated B+ and B- connections for an external battery.
The battery should be connected only to the designated B+ / B- connections. The +V / -V terminals are intended for the regulated DC output and should not be used as battery connections.
CN2 Temperature Sensor Connection
The CN2 connector is provided for an optional NTC temperature sensor used for charging-voltage temperature compensation.
CN2 uses a JST B2B-XH or equivalent connector, with a compatible JST XHP housing and JST SXH-001T-P0.6 terminal or equivalent.
If the temperature sensor is not connected, the charger continues to operate normally.
Mounting and Cooling
The SCP-75 Series is cooled by free-air convection.
The mechanical drawing provides the mounting-hole positions and enclosure dimensions required for equipment integration. Installation should allow the unit to operate within the specified temperature and derating conditions.
Operating Environment and Derating
The SCP-75 Series operates from -20°C to +60°C.
Output derating is required at higher ambient temperatures, and additional derating applies at low AC input voltage. The applicable load limits should be checked when the power supply is used near the upper operating-temperature range or at the lower end of the AC input range.
Need complete mechanical and wiring details? Review the SCP-75 mechanical drawing for mounting dimensions, terminal locations, battery connections, CN2 sensor connection and derating information.