KAA-8R
March 8, 2023KNX-20E-640
March 8, 2023MW Mean Well Meanwell KNX Universal Actuator KAA- 8R-S
Features
- 8 channel actuator in a compact size
- Suitable for various and mixed applications
- For AX, C-load, capacitive & inductive of loads
- Program via ETS5.0 software
- Support KNX data secure
- Manual control via Push button
- Programmable various time and scene function
- 3 years warranty
Mean Well KNX Universal Actuator KAA-8R-S Data Sheet Download
Description
The KNX actuator is a 8 channel device with high quality independent latching relay for switch, shutter or any possible mixed applications. The compact design with 4 units (72 mm) wide modular makes it suitable for installation in the distribution board on 35 mm mounting rails in the EIB / KNX application. The connection to the KNX bus is implemented via a bus connection terminal.The new version also supports KNX Data Secure function. KNX Data Secure offers protection against manipulation in building automation and can be configured in the ETS project.The switching relays are particularly suitable for switching ohmic loads, capacitive loads, for instance LED drivers and inductive loads as well as motors in shutter or blind applications.The actuator are poweredvia the EIB / KNX and do not require any additional power supply.
Mean Well KNX Universal Actuator KAA-8R-S Model Encoding
Type | Function | Note |
-10 | 4 channel actuator, 10A per channel | In stock |
Blank | 4 channel actuator, 16A per channel | by request |
Specification
ORDER NO. | KAA-8R-16S | KAA-8R-10S | ||
SUPPLY |
SAFETY MODEL NO. | KAA-8R-S | KAA-8R-10S | |
KNX BUS VOLTAGE | 21~31V | |||
CURRENT CONSUMPTION | <10mA | |||
POWER CONSUMPTION | <180mW | |||
Nr. OF SWITCHING OUTPUT | 8 | |||
Nr. OF SHUTTER OUTPUT | 4 | |||
OUTPUT TYPE | Independent, potential-free bistable(latching) relay | |||
OUTPUT SWITCHING RATINGS |
VOLTAGE | 230VAC@50Hz | ||
CURRENT | OHMIC LOAD | 16A | 10A | |
CAPACITIVE LOAD | 220μF(See Note.2) | 220μF(See Note.2) | ||
MAX. INRUSH CURRENT | 800A(max. 200μs),165A(max. 20ms) | 400A(max. 200μs),80A(max. 20ms) | ||
EN60947-4-1 AC1(COSθ=0.8) | 16A | 10A | ||
EN60947-4-1 AC3(COSθ=0.45) | 8A | 5A | ||
EN60947-4-1 AC5a(COSθ=0.45) | 8A | 8A | ||
EN60947-4-1 AC5b | 16A | 10A | ||
MAX. TOTAL CURRENT OF
THE ACTUATOR |
80A | 56A | ||
OUTPUT SERVICE LIFE |
MECHANICAL SERVICE LIFE | >106 | ||
ELECTRICAL ENDURANCE EN60669-1 19.1 | 104(See Note.2) | 4*104(See Note.2) | ||
EN60669-1 19.2 , FLOURSCENT LAMP(AX) | 104(See Note.2) | 104(See Note.2) | ||
OPERATING & DISPLAY | PROGRAMMING BUTTON/LED | Program the individual address | ||
MANUAL BUTTON/LED | Manual control and indication | |||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +45℃(3K5) | ||
STORAGE TEMP. | -35 ~ +70℃ | |||
WORKING HUMIDITY | 10 ~ 95% RH non-condensing | |||
PROTECTION CLASS | Ⅱ, According to EN61140 | |||
OVER VOLTAGE CATEGORY | Ⅲ , According to EN60664-1 | |||
POLLUTION DEGREE | 2, According to EN60664-1 | |||
DEGREE OF PROTECTION | IP20, According to EN60529 | |||
SAFETY & EMC |
SAFETY STANDARDS | BS EN/EN50491-3, BS EN/EN60669-1, BS EN/EN60669-2-1, BS EN/EN60669-2-5(See Note.2),
EAC TP TC 004 approved |
||
EMC EMISSION | Compliance to BS EN/EN50491-5-1, -2, -3, BS EN/EN50090-2-2, BS EN/EN60669-2-1, BS EN/EN60669-2-5, BS EN/EN63044-5-1, -2,-3(See Note.2), EAC TP TC 020 | |||
EMC IMMUNITY | Compliance to BS EN/EN50491-5-1, -2, -3, BS EN/EN50090-2-2, BS EN/EN60669-2-1, BS EN/EN60669-2-5, BS EN/EN63044-5-1, -2, -3(See Note.2), EAC TP TC 020 | |||
WITHSTAND VOLTAGE | Between switching and SELV control circuit:3.5KVAC | |||
CONNECTIONS |
SCREW TERMINAL | 0.5 – 4.0mm² solid core 0.5 – 2.5mm² finely stranded | ||
KNX BUS CONNECTION TERMINAL | 0.8mmψ, solid core | |||
OTHERS |
MTBF | 597.8K hrs min. Telcordia SR-332 (Bellcore); 447.9K hrs. min. MIL-HDBK-217F (25℃) | ||
DIMENSION | 72*90*57mm (W*H*D) | |||
MOUNTING WIDTH IN UNITS | 4 | |||
DIN RAIL MOUNTING | 35mm mounting rail according to DIN EN60715 | |||
PACKING | 0.312Kg; 48pcs/16Kg/1.02CUFT |
Applications
- Building Automation
- Lighting switch
- Shutter/Blind control
- Heating control
- Ventilation function