MEAN WELL LAD-240 Series 240W Security Power Supply with Battery Charger & UPS Function

The MEAN WELL LAD-240 Series is a low-profile 240W AC/DC security and fire alarm power supply with built-in battery charger and UPS backup function, designed for systems that require regulated DC power, battery charging and continued operation during AC mains interruption.

The series supports 90–132VAC or 180–264VAC input selectable by switch, with 240–370VDC input also supported, and is available in four output versions: LAD-240A with 13.8V output and up to 16.4A rated current, LAD-240B with 27.6V output and up to 7.7A, LAD-240C with 41.5V output and up to 4.78A, and LAD-240D with 55.2V output and up to 3.4A. Each model provides a dedicated 1A battery charging output and is suitable for lead-acid and lithium-ion batteries.

During normal AC operation, the LAD-240 supplies power to the connected load while charging the backup battery. If the AC input becomes abnormal, the built-in UPS function switches the power source to battery backup operation. The series also provides TTL status signals for AC OK, battery disconnect or reverse polarity, battery low, battery full and discharge status, together with a forced UPS mode for battery maintenance and system testing.

With a low-profile 215 × 115 × 30 mm design, efficiency up to 88%, built-in AC and battery circuit ON/OFF switches, and protection against short circuit, overload, overvoltage, overtemperature, battery low voltage and battery reverse polarity, the LAD-240 Series is suitable for fire emergency and evacuation systems, public safety battery backup, security systems, DC UPS systems, central monitoring systems and industrial automation.

MEAN WELL LAD-240 Series 240W security power supply with battery charger and UPS function
MEAN WELL LAD-240 Series 240W security and fire alarm power supply with battery charger and UPS backup function.

Key Highlights of LAD-240 Series

  • 240W AC/DC security and fire alarm power supply with built-in battery charger and UPS backup function
  • 90–132VAC or 180–264VAC input selectable by switch, with 240–370VDC input capability and up to 88% typical efficiency
  • Available as LAD-240A, LAD-240B, LAD-240C and LAD-240D with 13.8V, 27.6V, 41.5V and 55.2V outputs
  • Supports normal load powering, battery charging and automatic battery backup operation when AC mains becomes abnormal
  • TTL status signals provide AC OK, battery disconnect or reverse polarity, battery low, battery full and discharge monitoring
  • Forced UPS mode supports battery maintenance and system testing through the CN2 control interface
  • Built-in short circuit, overload, overvoltage, overtemperature, battery low-voltage and reverse-polarity protection
  • Low-profile 215 × 115 × 30 mm design for fire emergency, public safety backup, security, DC UPS, central monitoring and industrial automation systems

Overview of MEAN WELL LAD-240 Series

The MEAN WELL LAD-240 Series combines regulated DC output, dedicated battery charging, UPS backup control and system status monitoring in a low-profile 240W AC/DC power supply. It is designed for security, fire alarm and backup power applications that require normal DC operation together with automatic battery-supported operation when AC mains power becomes abnormal.

During normal AC operation, the LAD-240 supplies power to the connected load while charging the external battery. If the AC input becomes abnormal, the built-in UPS function switches the power source to battery backup, allowing connected equipment to continue operating during mains interruption. The series also supports a forced UPS mode for battery maintenance and system testing.

The series includes four models. LAD-240A provides a 13.8V main output rated at 16.4A, LAD-240B provides 27.6V at 7.7A, LAD-240C provides 41.5V at 4.78A, and LAD-240D provides 55.2V at 3.4A. Each model also provides a dedicated 1A battery charging output, and the series is suitable for use with lead-acid and lithium-ion batteries.

For system monitoring, the LAD-240 Series provides TTL status signals for AC OK, battery disconnect or reverse polarity, battery low, battery full and discharge status. Built-in protection functions include short circuit, overload, overvoltage, overtemperature, battery low-voltage protection and battery reverse-polarity protection. With a low-profile 215 × 115 × 30 mm design, built-in AC and battery circuit ON/OFF switches and efficiency up to 88%, the LAD-240 Series is suitable for fire emergency and evacuation systems, public safety battery backup, security systems, DC UPS systems, central monitoring systems and industrial automation.

Features

  • 240W AC/DC security and fire alarm power supply with dedicated main output and 1A battery charging output
  • 90–132VAC or 180–264VAC input selectable by switch, with 240–370VDC input capability and up to 88% typical efficiency
  • LAD-240A provides 13.8V main output rated at 16.4A
  • LAD-240B provides 27.6V main output rated at 7.7A
  • LAD-240C provides 41.5V main output rated at 4.78A
  • LAD-240D provides 55.2V main output rated at 3.4A
  • Built-in battery charger and automatic UPS backup operation during abnormal AC input
  • TTL status signals for AC OK, battery disconnect or reverse polarity, battery low, battery full and discharge monitoring
  • Forced UPS mode supports battery maintenance and system testing
  • Short circuit, overload, overvoltage, overtemperature, battery low-voltage and reverse-polarity protection
  • Suitable for lead-acid and lithium-ion batteries
  • Low-profile 215 × 115 × 30 mm design with built-in AC and battery circuit ON/OFF switches

Need help selecting the correct output voltage for your system? Compare LAD-240A, LAD-240B, LAD-240C and LAD-240D below.

LAD-240 Series Technical Specifications

The table below compares the main electrical specifications of the MEAN WELL LAD-240 Series, including main DC output, battery charging output, rated power, ripple and noise, voltage adjustment range and typical efficiency.

It helps users compare LAD-240A, LAD-240B, LAD-240C and LAD-240D when selecting a 240W security power supply with battery charger and UPS backup function.

Model Main Output Main Output Rated Current Battery Charger Output Charger Rated Current Rated Power Ripple & Noise Max. Voltage Adj. Range Efficiency Typ.
LAD-240A 13.8V 16.4A 13.8V 1A 240.12W 150mVp-p 10.8–14.5V 85.5%
LAD-240B 27.6V 7.7A 27.6V 1A 240.12W 150mVp-p 21.6–29V 87.5%
LAD-240C 41.5V 4.78A 41.5V 1A 239.87W 240mVp-p 32.4–43.5V 88%
LAD-240D 55.2V 3.4A 55.2V 1A 242.88W 240mVp-p 43.5–58V 88%
Common input specifications: 90–132VAC or 180–264VAC selectable by switch, with 240–370VDC input capability and a 47–63Hz frequency range. The default input selector position is 230VAC. Typical AC current is 4.4A at 115VAC and 2.4A at 230VAC. Cold-start inrush current is typically 60A at both 115VAC and 230VAC, while leakage current is below 0.5mA at 240VAC.
Output and regulation note: CH1 output voltage is adjustable by VR over an approximate -20% to +5% range. Voltage tolerance is ±1.5% for LAD-240A, ±1.0% for LAD-240B and LAD-240C, and ±0.5% for LAD-240D. Line regulation is ±0.5% across the series, while load regulation is ±1.0% for LAD-240A and ±0.5% for LAD-240B, LAD-240C and LAD-240D.
Battery and protection note: Battery low-voltage cut-off is 9.5V ±0.5V for LAD-240A, 21.5V ±0.5V for LAD-240B, 32V ±0.5V for LAD-240C and 43V ±0.5V for LAD-240D. The series also provides protection against short circuit, overload, overvoltage, overtemperature and battery reverse polarity.
Status monitoring note: TTL signals are available for AC OK, battery disconnect or reverse polarity, battery low, battery full and discharge status. The interface requires an external voltage source and supports up to 50VDC applied voltage with a maximum sink current of 30mA.
Environment and mechanical note: The LAD-240 Series operates from -20°C to +60°C, with output derating required at higher ambient temperatures. The low-profile enclosure measures 215 × 115 × 30 mm, making it suitable for security, fire alarm, DC UPS, public safety backup and central monitoring installations.

Need more technical details? Continue below for UPS backup operation, TTL status signals, forced UPS mode, battery protection functions, mechanical dimensions, connector assignments, safety approvals, EMC information and application guidance.

Model Selection Guide for LAD-240 Series

The MEAN WELL LAD-240 Series includes four 240W-class AC/DC power supply models with built-in battery charger and UPS backup function. Selection between LAD-240A, LAD-240B, LAD-240C and LAD-240D is primarily determined by the required DC output voltage, load current and battery charging requirements.

All four models share the same 90–132VAC or 180–264VAC input selectable by switch, with 240–370VDC input capability, 1A battery charging output, UPS backup function, TTL status monitoring, forced UPS mode, battery reverse-polarity protection and 215 × 115 × 30 mm low-profile design. The main differences are output voltage, rated current, rated power, voltage adjustment range, efficiency and battery low-voltage cut-off threshold.

LAD-240A – 13.8V Output

The MEAN WELL LAD-240A provides a 13.8V main output rated at 16.4A together with a 13.8V battery charging output rated at 1A. Rated power is 240.12W.

The main output voltage can be adjusted from 10.8V to 14.5V. Battery low-voltage cut-off is specified at 9.5V ±0.5V, and typical efficiency is 85.5%.

LAD-240A is generally selected when the connected load and battery backup architecture require the lowest output-voltage version in the LAD-240 Series together with the highest available load current.

LAD-240B – 27.6V Output

The MEAN WELL LAD-240B provides a 27.6V main output rated at 7.7A together with a 27.6V battery charging output rated at 1A. Rated power is 240.12W.

The main output voltage can be adjusted from 21.6V to 29V. Battery low-voltage cut-off is specified at 21.5V ±0.5V, and typical efficiency is 87.5%.

LAD-240B is suitable for systems requiring a 27.6V regulated output with integrated battery charging and UPS backup operation.

LAD-240C – 41.5V Output

The MEAN WELL LAD-240C provides a 41.5V main output rated at 4.78A together with a 41.5V battery charging output rated at 1A. Rated power is 239.87W.

The main output voltage can be adjusted from 32.4V to 43.5V. Battery low-voltage cut-off is specified at 32V ±0.5V, and typical efficiency is 88%.

LAD-240C is intended for higher-voltage backup power architectures requiring a 41.5V regulated output and integrated battery charging.

LAD-240D – 55.2V Output

The MEAN WELL LAD-240D provides a 55.2V main output rated at 3.4A together with a 55.2V battery charging output rated at 1A. Rated power is 242.88W.

The main output voltage can be adjusted from 43.5V to 58V. Battery low-voltage cut-off is specified at 43V ±0.5V, and typical efficiency is 88%.

LAD-240D is the highest-voltage model in the series and is suitable where the connected load and backup battery architecture require a 55.2V output.

How to Choose Between LAD-240A, LAD-240B, LAD-240C and LAD-240D

Start with the required DC output voltage. Choose LAD-240A for 13.8V, LAD-240B for 27.6V, LAD-240C for 41.5V or LAD-240D for 55.2V output.

Then confirm the required load current. LAD-240A provides up to 16.4A, LAD-240B up to 7.7A, LAD-240C up to 4.78A and LAD-240D up to 3.4A. All four models provide a dedicated 1A battery charging output.

When AC input is normal, the LAD-240 supplies the connected load while charging the external battery. When the AC input becomes abnormal, the built-in UPS function switches the system to battery backup operation.

Status Monitoring and UPS Control

All LAD-240 models provide TTL status signals for AC OK, battery disconnect or reverse polarity, battery low, battery full and discharge status. The TTL interface requires an external voltage source and supports up to 50VDC applied voltage with a maximum sink current of 30mA.

The series also provides a forced UPS mode through CN2 pins 7 and 8. Shorting these pins activates forced UPS operation, while leaving them open keeps the unit in normal operating mode.

Need help choosing the correct LAD-240 model? Start with the required output voltage, then confirm load current, battery charging requirements, backup operation and monitoring interface requirements.

Related MEAN WELL LAD, PSC and Security Power Supplies

For security systems, fire alarm systems, emergency power, central monitoring and battery backup applications, the following MEAN WELL power supplies can be compared with the LAD-240 Series according to required output power, output voltage, battery charging capability, UPS function, monitoring requirements and installation format:

  • LAD-120 Series – Lower-power LAD Series security and fire alarm power supply with integrated battery charger, UPS backup function and TTL status monitoring for applications requiring less output capacity than LAD-240.
  • LAD-360 Series – Higher-capacity LAD Series power supply for security, fire alarm and battery backup systems requiring greater load power and charging capability than LAD-240.
  • LAD-600 Series – High-power LAD Series security and emergency backup power solution for systems requiring substantially greater output capacity, battery charging and UPS operation.
  • PSC-35 Series – Lower-power AC/DC power supply with integrated battery charger and UPS backup function for security and battery-backed DC applications with lighter load requirements.
  • PSC-60 Series – Compact 60W power supply with battery charger and UPS function for applications requiring significantly lower output power than LAD-240.
  • PSC-100 Series – 100W battery charger power supply with UPS backup function for security, alarm and DC backup applications requiring lower output power.
  • PSC-160 Series – 160W AC/DC power supply with integrated battery charger and UPS backup function for systems requiring moderate output power below the LAD-240 Series.
  • DRC-60 Series – DIN rail AC/DC power supply with integrated battery charger and UPS function for systems that require TS35 rail installation.
  • DRC-100 Series – DIN rail security power supply with battery charging and automatic backup operation for applications that require DIN rail mounting rather than a low-profile chassis.
  • DRS-240 Series – Intelligent DIN rail security power supply integrating AC/DC power, battery charger, DC UPS, status monitoring and communication functions for more advanced backup power and supervisory applications.

Need help selecting the right MEAN WELL security power supply?
Compare LAD, PSC, DRC and DRS Series based on required output voltage, load power, battery charging current, UPS backup operation, status monitoring, communication functions and installation format.

Battery Backup and Status Monitoring Functions

The MEAN WELL LAD-240 Series integrates battery charging, UPS backup control and multiple TTL status signals for security, fire alarm and DC backup systems that require continued operation and external status monitoring during AC mains interruption.

Battery Backup Operation

During normal AC operation, the LAD-240 supplies power to the connected load while charging the external battery. If the AC input becomes abnormal, the built-in UPS function switches the power source to battery backup so the connected load can continue operating.

The series includes four output versions: LAD-240A at 13.8V, LAD-240B at 27.6V, LAD-240C at 41.5V and LAD-240D at 55.2V. Each model also provides a dedicated 1A battery charging output.

Battery protection note: An external fuse must be installed in series with the battery connection to provide the required battery-side protection.

TTL Status Monitoring

The LAD-240 Series provides multiple TTL status signals through the CN2 interface for external monitoring and control:

  • AC OK: Indicates whether the AC input is normal or abnormal
  • Battery Disconnect / Reverse Polarity: Detects battery connection status or reverse-polarity condition during initial power transmission
  • Battery Low: Indicates a low-battery condition
  • Battery Full: Indicates whether the battery is still charging or has reached full-charge status
  • Discharge: Indicates whether the system is operating from battery backup

The TTL interface requires an external voltage source and supports up to 50VDC applied voltage with a maximum sink current of 30mA.

Battery detection note: Battery disconnect and reverse-polarity status are checked during the initial power transmission rather than continuously during operation.

Battery Low-Voltage Cut-Off Protection

To help prevent excessive battery discharge during extended backup operation, the LAD-240 Series includes battery low-voltage cut-off protection:

  • LAD-240A: 9.5V ±0.5V battery cut-off
  • LAD-240B: 21.5V ±0.5V battery cut-off
  • LAD-240C: 32V ±0.5V battery cut-off
  • LAD-240D: 43V ±0.5V battery cut-off

The series also provides battery reverse-polarity protection. If the battery is connected with reversed polarity, the unit is protected from damage and recovers automatically after the fault condition is removed.

Forced UPS Mode

For battery maintenance and system testing, the LAD-240 Series provides a forced UPS mode through CN2 pins 7 and 8.

When pins 7 and 8 are shorted, the unit enters forced UPS mode. When the pins are open, the unit operates normally. This function allows the battery backup path to be tested without waiting for an actual AC mains failure.

Need wiring and connector details? Continue below to review the LAD-240 mechanical drawing, CN2 TTL signal pin assignment, terminal assignment and installation information.

MEAN WELL LAD-240 mechanical drawing with dimensions and terminal assignments
MEAN WELL LAD-240 Series mechanical drawing showing 215 × 115 × 30 mm dimensions, mounting points, terminal assignments and CN2 connector layout.

Mechanical Dimensions and Installation

The MEAN WELL LAD-240 Series uses a low-profile mechanical design intended for integration into security, fire alarm, battery backup and DC UPS equipment. At only 30 mm high, the unit can be installed in space-constrained enclosures while providing higher output capacity than lower-power LAD models.

Dimensions

The LAD-240 Series measures 215 × 115 × 30 mm (L × W × H) and uses Case No. 207.

The mechanical layout shows the mounting points, TB1 terminal block, CN2 signal connector, AC ON/OFF switch, battery connected/disconnected switch and airflow direction.

TB1 Terminal Assignment

The main AC input, DC output and battery connections are provided through the TB1 terminal block:

  • Pin 1: AC/L
  • Pin 2: AC/N
  • Pin 3: FG
  • Pin 4: DC OUTPUT -V
  • Pin 5: DC OUTPUT +V
  • Pin 6: BAT –
  • Pin 7: BAT +
Important wiring note: DC OUTPUT -V and BAT – must not be shorted together.

CN2 TTL Signal Assignment

The CN2 connector provides status monitoring and forced UPS control:

  • Pin 1: AC OK
  • Pin 2: Battery disconnect / reverse polarity
  • Pin 3: Battery Low
  • Pin 4: GND
  • Pin 5: Battery Full
  • Pin 6: Discharge
  • Pins 7 and 8: Open for normal operation; short for forced UPS mode

For CN2 connections, the specified mating housing is TKP DH2 or equivalent, with TKP DHT-1S(LF) or equivalent terminals.

Operating Environment and Airflow

The LAD-240 Series operates from -20°C to +60°C. Full-load operation is available through most of the operating range, with output derating required as ambient temperature approaches the upper limit.

The unit relies on the indicated airflow direction for thermal management. Enclosure design should therefore provide sufficient ventilation and avoid blocking the cooling path around the power supply.

Mounting and Installation

The mechanical drawing provides the key dimensions and mounting locations required for enclosure design, including the 215 mm overall length and 150 mm mounting spacing. Optional mounting brackets are also available where required.

Before final installation, confirm mounting clearance, wiring, grounding, battery protection, airflow and operating temperature for the actual equipment configuration.

Need exact mounting positions or connector details? Use the mechanical drawing above together with the official LAD-240 Series datasheet when preparing the final enclosure and wiring layout.

Applications

The MEAN WELL LAD-240 Series is designed for security, fire alarm and backup power applications requiring regulated DC output, battery charging, UPS operation and external status monitoring.

With LAD-240A, LAD-240B, LAD-240C and LAD-240D covering 13.8V, 27.6V, 41.5V and 55.2V output versions, the series provides a flexible 240W-class platform for systems that require continuous DC operation, battery-supported backup and TTL status detection.

  • Fire emergency and evacuation systems requiring reliable DC power, battery charging and backup operation during abnormal AC input
  • Security systems requiring regulated DC power together with battery backup and system status monitoring
  • Public safety battery backup systems requiring continued operation from an external battery during AC mains interruption
  • Uninterruptible DC-UPS systems requiring automatic transfer to battery-supported operation when AC input becomes abnormal
  • Central monitoring systems using TTL signals for AC OK, battery disconnect or reverse polarity, battery low, battery full and discharge monitoring
  • Industrial automation systems requiring regulated DC output, battery charging and backup power integration

Need safety and compliance details for your project? Continue below to review protection functions, safety approvals, EMC compliance and operating environment specifications for the LAD-240 Series.

Certifications and Safety

The MEAN WELL LAD-240 Series is a 240W AC/DC security and fire alarm power supply with integrated battery charging, UPS backup and status monitoring functions for systems requiring continued DC operation during abnormal AC input conditions.

The series is approved to UL62368-1, BS EN/EN62368-1, AS/NZS62368.1 and EAC TP TC 004. Its design also refers to GB 17945-2010 system requirements.

Safety and EMC Compliance

The LAD-240 Series is specified with the following safety and EMC standards:

  • UL62368-1 safety approval
  • BS EN/EN62368-1 safety approval
  • AS/NZS62368.1 safety approval
  • EAC TP TC 004 safety approval
  • GB 17945-2010 referenced in the product design requirements
  • BS EN/EN55032 (CISPR32) Class A conducted and radiated EMC emissions
  • BS EN/EN61000-4-2, -4-3, -4-4, -4-5, -4-6 and -4-8 EMC immunity tests
  • EAC TP TC 020 EMC requirements
Important EU compliance note: The LAD-240 Series does not meet the harmonic current requirements of BS EN/EN61000-3-2 under the conditions identified by MEAN WELL. This may restrict its use in certain equipment connected to public mains in the European Union, particularly equipment with average or continuous input power above 75W and lighting-system applications. Check the official LAD-240 documentation for the complete conditions and exceptions before final equipment certification.

Isolation and Electrical Safety

The LAD-240 Series provides the following withstand voltage levels:

  • Input to output: 3KVAC
  • Input to FG: 2KVAC
  • Output to FG: 0.5KVAC

Isolation resistance is specified at 100MΩ between input-output, input-FG and output-FG when tested at 500VDC, 25°C and 70% RH.

Protection Functions

The LAD-240 Series includes protection against short circuit, overload, overvoltage, overtemperature, battery low voltage and battery reverse polarity.

Overload behavior depends on battery connection and total output loading. With a battery connected, CH1 overload can cause the unit to enter UPS mode when CH1 reaches approximately 105% to 120%. When the combined CH1 and CH2 output reaches approximately 125% to 135%, the output shuts down. Without a battery connected, CH1 overload causes the output to shut down and requires the unit to be re-powered after the fault condition is removed.

CH2 uses constant-current limiting, and a CH2 fault does not affect CH1 operation. The charger output recovers automatically after the fault condition is removed. An external fuse is mandatory in series with the battery connection for protection.

Overvoltage and overtemperature protection shut down the output and require the power supply to be re-powered after the fault condition is removed. Battery reverse-polarity protection prevents damage and automatically recovers after the fault condition is removed.

Operating Environment and Final Equipment Integration

The LAD-240 Series operates from -20°C to +60°C, with output derating required at higher ambient temperatures.

Because the LAD-240 is a component power supply, EMC performance must be confirmed again in the final equipment. Wiring, grounding, enclosure layout, thermal conditions and airflow can all affect the completed system.

For EMC validation, MEAN WELL specifies defined mounting and wiring conditions during testing, including additional magnetic components on the battery output wiring for radiated-emission testing. Final equipment should therefore be evaluated under its actual installation conditions.

Need more product details before sending an inquiry? Continue below to review model comparison, battery backup operation, TTL status signals, forced UPS mode, mechanical dimensions, installation guidance and application information for the LAD-240 Series.

FAQ

What is the difference between LAD-240A, LAD-240B, LAD-240C and LAD-240D?

The main difference is the output voltage and corresponding rated load current. LAD-240A provides 13.8V at 16.4A, LAD-240B provides 27.6V at 7.7A, LAD-240C provides 41.5V at 4.78A, and LAD-240D provides 55.2V at 3.4A. All four models include a dedicated 1A battery charging output, UPS backup function, TTL status monitoring and forced UPS mode. Model selection should therefore start with the required system voltage, then confirm load current and battery requirements.

Does the MEAN WELL LAD-240 Series include a built-in battery charger?

Yes. The LAD-240 Series includes a dedicated 1A battery charging output in addition to the main DC output. The series is suitable for lead-acid and lithium-ion batteries. The external battery must be selected and protected according to the application requirements and the official MEAN WELL datasheet.

How does the UPS function work on the LAD-240 Series?

During normal AC operation, the LAD-240 supplies the connected load while charging the external battery. If the AC input becomes abnormal, the built-in UPS function switches the system to battery-supported operation so the connected equipment can continue operating. The series also provides discharge status monitoring through the TTL interface.

What input voltage does the LAD-240 Series support?

The LAD-240 Series supports 90–132VAC or 180–264VAC selected by switch, with the input selector set to 230VAC by default. It also supports 240–370VDC input. Unlike some universal-input power supplies, the LAD-240 requires the correct AC input range to be selected before operation.

What TTL status signals are available on the LAD-240 Series?

The LAD-240 Series provides TTL signals for AC OK, battery disconnect or reverse polarity, battery low, battery full and discharge. These signals are available through the CN2 connector and can be used by external controllers, alarm panels or monitoring systems. The TTL interface requires an external voltage source with a maximum applied voltage of 50VDC and maximum sink current of 30mA.

Can the LAD-240 battery backup function be tested without disconnecting AC power?

Yes. The LAD-240 Series provides a forced UPS mode through CN2 pins 7 and 8. Shorting pins 7 and 8 activates forced UPS mode, while leaving them open keeps the unit in normal operation. This function is useful for battery maintenance, commissioning and backup-path testing.

What battery low-voltage cut-off levels are used by LAD-240A, B, C and D?

Battery low-voltage cut-off is approximately 9.5V ±0.5V for LAD-240A, 21.5V ±0.5V for LAD-240B, 32V ±0.5V for LAD-240C and 43V ±0.5V for LAD-240D. The cut-off function helps prevent excessive battery discharge during extended backup operation.

What protection functions are built into the LAD-240 Series?

The LAD-240 Series includes protection against short circuit, overload, overvoltage, overtemperature, battery low voltage and battery reverse polarity. The datasheet also specifies different overload behavior depending on whether a battery is connected. An external fuse is mandatory in series with the battery connection.

What are the dimensions of the MEAN WELL LAD-240 Series?

The LAD-240 Series measures 215 × 115 × 30 mm (L × W × H) and uses a low-profile 30 mm enclosure. The mechanical drawing also provides TB1 terminal locations, CN2 connector position, AC and battery switches, airflow direction and mounting dimensions for integration into the final system enclosure.

Is the LAD-240 Series suitable for use in European equipment?

The LAD-240 Series carries several safety and EMC approvals, including UL62368-1, BS EN/EN62368-1, AS/NZS62368.1 and EAC requirements. However, the official datasheet states that the LAD-240 Series does not meet the harmonic current requirements of BS EN/EN61000-3-2 under certain conditions. For equipment intended for the European Union and connected to public mains, designers should review the datasheet restrictions and exceptions carefully before final product integration.

Need more details about LAD-240A, LAD-240B, LAD-240C or LAD-240D output voltage, battery charging current, UPS backup operation, TTL status signals, battery low-voltage cut-off, forced UPS mode, protection functions and installation? Check the FAQs above or review the official datasheet for complete electrical, battery backup, status monitoring, mechanical and installation specifications.

Product Video

MEAN WELL LAD-240 Series Power Supply Unboxing

MEAN WELL LAD-240 Series Power Supply Video Show

LAD-240 Series product videos will be added soon.

Request a Quote

Need pricing, stock availability, lead time, or project support for the MEAN WELL LAD-240 Series? Continue below to send your inquiry for LAD-240A, LAD-240B, LAD-240C or LAD-240D, including your required quantity, output voltage, load current, battery charging requirements, backup operation, TTL status monitoring requirements, and application details.